Manage stand orders
Select Option

RheoMeditech Inc.

32 Anam-ro, Dongdaemoon-gu, 02578 Seoul
Korea, Republic
Telephone +82 2 5375111
Fax +82 2 5375103
info@rheoscan.com

Submit your contact details

Provide your contact details to the exhibitor. Optionally, you may also add a personal message.

Please log in

You must be logged in to send the contact request.

An error has occurred

Please check your internet connection or try again later.

Message has been sent

Your message to the exhibitor was sent successfully.

Contact

Han Na S.

Phone
82-2-537-5111

Email
info@any-sis.com

Our range of products

Product categories

  • 03  Diagnostic tests
  • 03.03  Haematology / histology / cytology testing
  • 03.03.01  Haematology analyzers

Our products

Product category: Haematology analyzers

Diabetic complication Screening Assay - RheoSCAN

RheoSCAN
DIABETIC COMPLICATION SCREENING ASSAY in LESS THAN A MINUTE
•Diabetic Nephropathy
•Diabetic Retinopathy
•Metabolic syndrome



[ Innovative Technology for Hemorheology ]

RheoSCAN-AnD300 can measure comprehensive rheological properties of blood within a short time (< 2 min). Now, RBC deformability, aggregation and aggregating force can be easily measured with a leading-edge microfluidic technology.



• Deformability : EI@3Pa, EImax, t1/2
• Aggregation : AI, M, ESR, t1/2
• Aggregating force : critical shear stress (CSS)
• Due to the quick and easy operation, RheoSCAN can be used at research laboratories and clinical environments.


RBC Deformability
- Sample volume :5㎕
- Testing Time : 30 s
- Microfluidic
- Laser Diffraction

RBC Aggregation
- Sample volume : 8㎕
- Testing time : 120 s
- Microfluidic Stirring
- Light Transmission

Critical Shear Stress
- Sample volume : 500㎕ (=0.5mL)
- Testing Time : 30 s
- Microfluidic shearing
- Light Backscattering



[ RheoSCAN Features ]

EARLY DETECTION
- RheoScan system shows significantly high correlation with DKD, DR, and MetS through CSS

FAST
Rapid test: the test takes less than a minute (30~60, 120 seconds)

SIMPLE AND EASY
- One step of pipetting
- Disposable microchip
- Automated operation

TARGETED
- Diabetes Mellitus
- Diabetic Complications
- Diabetic Retinopathy (eye)
- Diabetic Nephropathy (kidney)
- Metabolic Syndrome
- Anyone who want's to check their health status


Visit our website for more information
www.rheoscacn.com
www.any-sis.com/rheoscan

More Less

Product category: Haematology analyzers

Platelet Function Test - Anysis

Anysis System is a platelet function testing system that measures bleeding risk managing assessments, and anti-platelet therapy response assessments for inherited, acquired, or drug-induced platelet dysfunction. Through in-vivo vascular mimicking microfluidics, the system measures a realistic primary hemostasis associated with platelet function.

▶ Test Types 
•  Anti-platelet Therapy Response Assessment
   Anysis-Aspirin
   Anysis-P2Y12 
•  Bleed Risk Screening
   Anysis-C/ADP
   Anysis-C/Epinephrine

Test Time: less than 5 minutes
The device includes two kit insertions which makes it possible to run two tests at a time.
Requiring blood sample: 200uL (sodium citrated)

▶ Key Features
1) Fully Automated System : With a single pipetting, the whole test is automatically operated
2) Bubble-free Test : Air bubbles in blood sample are naturally excluded in the test
3) Hematocrits-independent : Hematocrit variations do not affect the measurement of Anysis
4) Operator-independent Results : Measurements are not affected by operator's skillfulness
5) Stenosed Thrombosis Model : Flow through microbeads mimics stenosed vascular thrombosis
6) Platelet-adhesion Characteristic : Adhesion characteristic is fully emphasized in microscale pores


Upstream activation, which frequently occurs in pathological vascular environments, can be mimicked by adopting a shear-generating stirrer in a sample chamber.
After activation, the blood flows through a microfluidic tube including a flow-closure section consisted of ECM-coated microbeads. Typical ECMs are collagen and fibrinogen.
Downstream Adhesion of activated platelets occurs, followed by aggregation of platelets.
As the adhesion and aggregation of platelets continues, the flow paths through packed microbeads are gradually blocked and the blood flow eventually stops.
Measurement of how far the blood has migrated is the index for assessing the platelet function. The longer the distance migrated, the stronger the dysfunction of the platelets.

More Less

Product category: Haematology analyzers

Erythrocyte sedimentation Rate - RheoESR

RheoESR
Erythrocyte Sedimentation Rate

ESR in 20 SECONDS BY RED CELL AGGREGATION
Body inflammation /Immune response system
Chronic disease, an immune disorder, or other medical condition

More Less

About us

Company details

RheoMeditech Inc. specializes in blood test IVD devices (Anysis, RheoSCAN, and RheoESR) for hemostasis, thrombosis and screening for diabetic complications.

We are looking for business partners (distributors, investors, collaborators).

More Less

Company data

Sales volume

100-199 Mio US $

Export content

max. 75%

Number of employees

1-19

Area of business
  • Laboratory Equipment
  • Diagnostics